  • Arid Technologies - ARID's PERMEATOR installed at ERG Petroli S.p.A's Station in Italy...
    management of new facilities and implements the highest health and safety standards By adopting the PERMEATOR technology ERG has again demonstrated its commitment to customers and the environment The PERMEATOR will reduce emissions from the underground storage tanks at ERG s fueling sites contributing to the health and well being of its customers employees and preserving its petroleum investment The PERMEATOR The ingestion of excess air occurs during normal operation of Stage II vacuum assist vapor recovery systems resulting in hydrocarbon emissions These emissions represent a potential health and safety hazard for the public as well as an economic burden to petroleum marketers who are unable to sell the same volume of product as originally purchased ARID s PERMEATOR system provides the solution to both of these issues states Ted Tiberi President of ARID Technologies Inc Although Stage II vapor recovery systems are effective in capturing vapors displaced from automobile storage tanks during vehicle refueling operations the excess air can cause significant evaporative emissions of product said Tiberi Anthony Mannara Global Business Development Director for ARID added It is encouraging to see the leaders in the energy and petroleum industry invest in technological advances that protect the environment Italy has the largest number of gasoline stations in Europe and ERG s PERMEATOR installation addresses the issues of Volatile Organic Compound emissions and evaporative losses providing a win win solution for the public and the station owners The PERMEATOR s patented hydrocarbon selective membrane prevents the venting of gasoline vapors known as Volatile Organic Compounds VOCs as well as the associated product loss from gasoline storage tanks The system virtually eliminates evaporative emissions and has been proven since 1989 in large tank storage and refinery applications A recent third party study conducted in Florida concluded that evaporative losses can be as

    Original URL path: http://www.aridtech.com/news_erg.html (2016-02-15)
    Open archived version from archive


  • Arid Technologies - ARID Receives Certification from Maryland...
    problem by selectively separating air from hydrocarbons exhausting clean air to the atmosphere and returning enriched hydrocarbon vapors to the gasoline storage tanks ARID s President Founder Ted Tiberi said In comparison to other approved alternatives such as monitoring wells and soil vapor extraction systems PERMEATOR represents an elegant solution to this pervasive contamination problem In addition to reducing groundwater contamination and air pollution PERMEATOR provides a rapid payback on invested capital by recovering high concentrations of hydrocarbon vapors and allowing petroleum marketers to re sell the same volume of product which they purchased via the bulk tanker A typical refueling site operator can save 10 to 20 gallons per day of fuel by using PERMEATOR For larger refueling sites the savings can measure up to 40 gallons per day Newly constructed gasoline refueling sites located in Anne Arundel Baltimore Carroll Cecil Charles Calvert Frederick Harford Howard Montgomery and Prince George s counties must either Submit required documents to demonstrate the storage system does not pose a threat or Comply with the following a Test the system for vapor leaks using the MDE protocol prior to start up b Use interstitial monitoring c Implement one of the following i Install three or more groundwater monitoring wells ii Install a pressure control device or iii Install a soil vapor extraction system d Additionally UST s with a capacity 2 000 gallons or for multiple tanks in the same tank excavation install four monitoring pipes connected in a manner that allows for the rapid installation of a soil vacuum extraction system Within 30 days a Sample the site supply well and any monitoring wells b Test for leaks all spill catch basins and containment sumps Yearly a Test for vapor leaks using the MDE protocol b Sample the site supply well and

    Original URL path: http://www.aridtech.com/news_maryland.html (2016-02-15)
    Open archived version from archive

  • Arid Technologies - ARID's PERMEATOR System Earns CARB Certification
    PERMEATOR validates our design philosophy of using only robust reliable and quality components Moreover savvy petroleum marketers have already realized the PERMEATOR s dual benefit of reducing harmful environmental emissions while at the same time yielding direct financial benefits via gasoline fuel savings The certification test was conducted at a retail refueling site located in Grass Valley California The site manager Mr Descoe Chentnik commented PERMEATOR has been generating fuel savings of approximately 1 000 gallons per month The unit has operated maintenance free for over three years Steve Matus who was ARID s liaison with CARB personnel stated Although it was a long and arduous path for certification we are very thankful to have had the opportunity to work with such a professional staff Without the knowledge and expertise of George Lew Pat Bennett and Paul Marzilli it would have been much more difficult to navigate through the administrative process of certification We had confidence in our product and we knew through diligence and patience the certification would be granted About ARID Technologies ARID Technologies Inc is a recognized leader in membrane based gasoline vapor recovery technology Based in Wheaton IL ARID has over 196 of it s PERMEATOR systems installed worldwide including locations in Europe and Asia internationally and domestically in California Nevada Texas Florida Virginia Delaware Maryland Pennsylvania New Jersey and New Hampshire For more information please reference ARID s website at www ARIDtech com or call the company at 630 681 8500 About CARB California s Legislature established the Air Resources Board ARB in 1967 to attain and maintain healthy air quality and to conduct research into the causes of and solutions to air pollution Since its formation the ARB has worked with the public the business sector and local governments to protect the public s

    Original URL path: http://www.aridtech.com/news_carb.html (2016-02-15)
    Open archived version from archive

  • Arid Technologies - Texas ORVR Certification Approval
    emissions of product said ARID president Ted Tiberi He added These emissions are a health and safety hazard for the public as well as an economic burden to petroleum marketers who will not be able to sell the same volume of product that they originally purchased ARID s PERMEATOR system provides the solution to both of these issues All Stage II vapor recovery systems installed on refueling stations located within the Texas counties of Brazoria Chambers Fort Bend Galveston Harris Liberty Montgomery Waller Hardin Jefferson Orange El Paso Collin Dallas Denton and Tarrant must be ORVR Compatible according to the following schedule Stage II vapor recovery systems installed on or after April 1 2005 must be ORVR compatible and Stage II vapor recovery systems installed before April 1 2005 must be upgraded to an ORVR compatible system no later than April 1 2007 The PERMEATOR prevents the venting of gasoline vapors VOC s volatile organic compounds and associated product loss from gasoline storage tanks through a patented hydrocarbon selective membrane The system virtually eliminates evaporative emissions and has been proven since 1989 in large tank storage and refinery applications A recent independent third party study conducted in Florida determined that

    Original URL path: http://www.aridtech.com/news_texas.html (2016-02-15)
    Open archived version from archive

  • Arid Technologies - Vent Line and Fugitive Emission Field Tests in Asia
    Emission Field Tests in Asia Vent Line and Fugitive Emission Field Tests in Asia were conducted at both a Stage II dispenser based system location as well as a Centralized vacuum system site The results analysis from these tests will

    Original URL path: http://www.aridtech.com/news_asia.html (2016-02-15)
    Open archived version from archive

  • Arid Technologies - Membranes, Molecules and the Science of Permeation - Page 2
    more significant as the population of ORVR equipped vehicles increases Stage II ORVR V L RVP psia Storage Tank Temp F Refueling Emissions Tons yr station Evap Emissions Tons yr station Total Emissions Tons yr station Recovery No No 11 65 5 04 4 44 9 48 0 No Yes 11 65 0 25 4 44 4 69 50 Yes No 1 2 11 65 0 25 2 38 2 63 72 Yes Yes 1 05 9 65 0 25 0 92 1 17 88 Yes Yes 1 3 9 65 0 25 2 73 2 98 68 Yes Yes 1 05 13 70 0 25 6 26 6 51 31 Yes Yes 1 3 13 70 0 25 10 76 11 01 N A 1 Uncontrolled refueling emissions estimated at 8 4 lb HC per 1 000 gallons dispensed EPA CARB 2 From ARID s Evaporative Loss Model 3 Assuming 95 percent capture efficiency of uncontrolled refueling emissions Percentage computation not applicable because evaporative emissions 10 76 exceed base 9 48 Table 1 Magnitude of Evaporative Vapor Emissions Monthly Gasoline Volume of 100 000 Gallons Membrane vapor processing technology Working with a leading European research institute ARID Technologies has designed a vapor recovery system for gasoline storage tanks using a selectively permeable membrane The membrane technology has been proven to be effective over many years in large storage tanks at bulk plants and refineries ARID has simplified this technology for the retail service station environment This system called PERMEATOR separates hydrocarbon vapors from air exhausts the cleaned air to the atmosphere and returns the enriched hydrocarbon vapors to the storage tank head space By selectively removing air from the storage tank head space storage tank pressures are reduced and fugitive and vent emissions are virtually eliminated The system is installed on manifolded tank vent lines It can be used at uncontrolled stations no Stage II as well as Stage II compliant facilities using balance or vacuum assist dispenser based and centralized vapor recovery systems The selectively permeable membrane material is positioned in a compact module that exhibits very low pressure drop and excellent mass transfer characteristics The entire system is housed in a relatively small enclosure measuring four feet W x two feet H x two feet D that can typically be installed without any excavation Energy consumption is minimized since all streams enter and exit the membrane in vapor phase Normal operation of the vent lines is not impeded because the system is installed parallel to the vents No restriction whatsoever is created in the vapor pathway Six PERMEATOR systems are currently in operation one in the US and the others overseas as part of test programs The units are being monitored to verify ARID s projected overall estimates of vapor recovery efficiency of 95 percent Fig 1 Membrane System Note As tank pressure decreases to a pre set level the pressure switch automatically deactivates the PERMEATOR system The above sequence is repeated when the storage tank pressure

    Original URL path: http://www.aridtech.com/membranes2.html (2016-02-15)
    Open archived version from archive


  • 27 3 423 961 38 7 55 11 32 2 18 4 55 11 08 0 059 Storage Tank Evaporative Losses 1999 CARB Study Total Hydrocarbon Emissions from Two Phase II Vacuum Assist Vapor Recovery Systems During Baseline Operation and Simulated Refueling of On Board Refueling Vapor Recovery O RVR Equipped Vehicles Project Number ST 98 XX Compliance Division D E F a b value explanation since the p v ON data did not yield meaningful data due to gross leaks until after 3 00 pm during the data collection period data collection started at 10 00 am ARID extrapolated the meaningful data time interval to calculate the 2 031 lbm 1000 gallon figure at propane C3H8 The gross leaks were not fixed until 3 00 A B C February 05 February 05 Gilbarco Dresser Wayne Dresser Wayne ARID Test Gilbarco ARID Test Gilbarco ARID Evap Loss Model PV ON PV ON PV OFF PV ON PV OFF PV OFF lbm 1 000 gal lbm 1 000 gal lbm 1 000 gal lbm 1 000 gal lbm 1 000 gal lbm 1 000 gal Baseline 0 396 0 028 0 026 44 9 ORVR penetration 0 782 39 5 ORVR

    Original URL path: http://www.aridtech.com/study_lantana_table1.html (2016-02-15)
    Open archived version from archive

  • ARID Technologies - Lantana, Florida Study - Permeator On Vs. Off Graph
    HOME ABOUT

    Original URL path: http://www.aridtech.com/study_lantana__onvsoff.html (2016-02-15)