archive-com.com » COM » A » AUTOCLAVEENGINEERS.COM

Total: 91

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Core Disolving/Removal System
    caustic solutions Any system involving a high pressure vessel or stirred reactor Core Disolving Removal System Custom Applications Core Removal Cleaning Systems FEATURES Operating temperatures up to 450 F 232 C Operating Pressures to 500 psi 35 bar with higher pressures available upon request Sizes to 125 gallons 473 Liters Quick opening closures Cover handling with rotation Vessels are fitted with internal or external electric heaters and thermally insulated Systems come complete with vessel stand controls and product basket Vessels constructed with Stainless Steel nickel INCONEL or other materials available INCONEL is a registered trademark of Special Meatals Corporation Touch Screen control with PC based data acquisition ASME CE TUV or other applicable code stamps are available BENEFITS A Core Removal System with an Interrupted Lug Closure is a quick opening vessel available with the ASME Code Stamp Custom sizes and materials of construction can be ordered and basket agitation which improves processing time is available if required Automated recipe control and data acquisition software make this a high tech solution to your process needs Match any search words all search words Results per page 10 20 100 Parker Autoclave Engineers Research Tools Products 8325 Hessinger Drive Erie Pennsylvania 16509

    Original URL path: http://www.autoclaveengineers.com/products/custom_applications/core_disolving_removing/index.html (2016-04-26)
    Open archived version from archive


  • Subsea Simulation Vessel
    opening closures available ASME CE TUV or other applicable code stamps are available Cooling jackets Closed loop flow systems including pumps Automated PC or PLC based control system with data acquisition BENEFITS Parker Autoclave Engineers specializes in custom engineering and will design a Sub Sea Simulation System to meet specific requirements These single or double ended vessels are suitable for either vertical or horizontal operation Available in a variety of

    Original URL path: http://www.autoclaveengineers.com/products/custom_applications/subsea_simulation/index.html (2016-04-26)
    Open archived version from archive

  • Agency Approvals
    certifications FEATURES AED Design practices conform to all requirements of ASME Code Section VIII Division 1 2 or 3 A Professional Engineer signs off ASME code calculations prior to submission to the code inspector when required The Engineering Department utilizes linear and non linear Finite Element Analysis as part of many pressure vessel designs European compliance is accomplished by designing in accordance with the CE regulations and the Pressure Equipment Directive PED 97 23 EC modules A1 D1 H H1 Canadian Registration Numbers CRN are obtained as required by Parker Autoclave Engineers customers in Canada BENEFITS Nearly every customer throughout the world can purchase pressure vessels from Parker Autoclave Engineers that meet the specific design standards in their state province or country Customers in areas where no design restrictions or code standards exist will still receive pressure vessels designed to meet the toughest standards in the industry Parker Autoclave Engineers typically overdesigns pressure vessels wherever possible so that if future re machining is required the vessel often will still be able to meet ASME code requirements without de rating the vessel Match any search words all search words Results per page 10 20 100 Parker Autoclave Engineers Research Tools Products

    Original URL path: http://www.autoclaveengineers.com/products/custom_applications/agency_approvals/index.html (2016-04-26)
    Open archived version from archive

  • Parker Autoclave Engineers: PDF Listing
    Mag 2 75 Production Scale High Pressure Magnetic Mixer Stirred Reactors Mini Reactors Ordering Guide Mini Reactor s Zipperclave Stirred Laboratory Reactor 500 1L 2 4L Ordering EZE Seal Stirred Laboratory Reactor 100 300 500 1000 2 000 4 000 Bolted Closure Laboratory Reactors 100 300 500 1L 2 4L Ordering Stirred Reactor Conversion Kits Stirred High Pressure Precontacting Pot High Temperature Bolted Closure Batch Reactor High Temperature Bolted Closure Batch Reactor Catalyst Testing Reactors Berty Stationary Basket Catalyst Reactor MicroBerty Catalyst Testing Reactor Robinson Mahoney Catalyst Testing Reactor Micro Robinson Mahoney Catalyst Reactor Mahoney Robinson Spinning Basket Reactor Carberry Spinning Basket Catalyst Reactor Harshaw Falling Basket Catalyst Reactor Caldwell Catalyst Testing Reactor MicroClave Catalyst Testing Reactor Laboratory Reaction Systems BTRS Jr Laboratory Tube Reactor System Multi Reactor Systems BTRS Jr PC BTRS 900 Automatic Tube reactor System BTRS Jr Technical Manual Process Instrumentation Sentinel Series Controller Watchtower Software UTD Universal Tach Display UMC Universal Motor Controller UFC Universal Flow Controller High Pressure Pumps MagnePump 3 4 HP MagnePump 5 HP Spare Parts Standard Renewal Parts Custom Components Customer Support Services Inspection Testing and Recertification Repair and Refurbishment Installation and Training Technical Support Custom Applications High Pressure Impregnation System Low

    Original URL path: http://www.autoclaveengineers.com/html/pdflisting.html (2016-04-26)
    Open archived version from archive

  • Parker Autoclave Engineers: Legal Policy
    us at 814 860 5700 Dispute Resolution and Privacy Seals We have the following privacy seals Privacy Dispute Use the contact e mail if you feel we have misrepresented our privacy policy Additional Information This policy is valid for 1 week from the time that it is loaded by a client Data Collection P3P policies declare the data they collect in groups also referred to as statements This policy contains 2 data groups The data practices of each group will be explained separately Group Microsoft IIS Web Server Log We collect the following information URI of requested resource Request date Request time Complete host and domain name Full IP address HTTP request method Data bytes in response Response status code User agent information This data will be used for the following purposes Anonymous user analysis This data will be used by ourselves and our agents The data in this group has been marked as non identifiable This means that there is no reasonable way for the site to identify the individual person this data was collected from The following explanation is provided for why this data is collected Our Microsoft IIS web server collects normal browser log information We generate private usage statistics from this log Group PDF Contact Form We collect the following information HTTP cookies User s Name User s Job Title Organization Name Mailing address Business telephone numbers Online Address Information This data will be used for the following purposes Contacting visitors for marketing of services or products The user must opt in to this usage Telemarketing The user must opt in to this usage This data will be used by ourselves and our agents The following explanation is provided for why this data is collected User s of autoclave com may request detailed PDF literature We

    Original URL path: http://www.autoclaveengineers.com/html/legal.html (2016-04-26)
    Open archived version from archive

  • Site Map Page 1 - Generated by www.xml-sitemaps.com
    About Us Parker Autoclave Engineers Plugins Needed for our Site Parker Autoclave Engineers Legal Policy Untitled Document Parker Autoclave Engineers PDF Listing catalytic reactors 1 pages Catalyst Reactors berty stationary basket 1 pages Berty Stationary Basket Catalyst Reactor caldwell catalyst testing 1 pages Caldwell Catalyst Testing Reactor carberry spinning basket 1 pages Carberry Spinning Basket Catalyst Reactor harshaw falling basket 1 pages Harshaw Falling Basket Catalyst Reactor mahoney robinson spinning 1 pages Mahoney Robinson Spinning Basket Reactor micro berty 1 pages Micro Berty Catalyst Testing Reactor micro robinson mahoney 1 pages Micro Robinson Mahoney Catalyst Reactor microclave catalyst testing 1 pages Microclave Catalyst Testing Reactor robinson mahoney catalyst 1 pages Robinson Mahoney Catalyst Testing Reactor custom applications 1 pages Custom Applications agency approvals 1 pages Agency Approvals core disolving removing 1 pages Core Disolving Removal System corrosion test system 1 pages Corrosion Test System down hole simulation 1 pages Down Hole Simulation System high press impreg sys 1 pages High Pressure Impregnation System hydrothermal crystal growth 1 pages Hydrothermal Crystal Growth System low density poly ldpe 1 pages Low Density Polyethylene LDPE Vessels subsea simulation 1 pages Subsea Simulation Vessel customer support 1 pages Customer Support Services inspection testing 1 pages Inspection testing and recertification installation training 1 pages Installation and Training repair 1 pages REPAIR AND REFURBISHMENT techncial support 1 pages Technical Support high press pumps 1 pages High Pressure Pumps magnepump 34 1 pages MagnePump 3 4 HP magnepump 5 1 pages MagnePump 5 HP hitemp bolted closure reactor 1 pages High Temperature Bolted Closure Laboratory Batch Reactors hitemp Bolted Closure 1 pages High Temperature Bolted Closure Laboratory Batch Reactors laboratory reaction systems 1 pages Laboratory Reaction Systems btrs900 1 pages BTRS 900 Automatic Tube Reactor System btrs jr Laboratory 1 pages BTRS JR LABORATORY REACTOR SYSTEMS btrs

    Original URL path: http://www.autoclaveengineers.com/sitemap.html (2016-04-26)
    Open archived version from archive

  • Stirred Reactors
    stamp option Click here to view Product Information High Temperature Bolted Closure Laboratory Batch Reactors The highest temperature and pressure rating of the standard stirred laboratory reactors The High Pressure Bolted Closure reactors permit research to be conducted at extremely high temperatures and pressures Parker Autoclave Engineers has designed this line of reactors and specified the valves fittings and tubing to be capable of 5 000 psi at up to 950 F 345bar 510 C Click here to view Product Information EZE Seal Stirred Laboratory Reactor Seal this 100 to 4 000 ml high pressure laboratory reactor with low torque A standard high temperature laboratory batch reactor 3 300 psig 227 bar pressure rating 850 F 454 C temperature rating Optional metal seals Catalytic conversion kits optional equipment Magnetic mixer 3 300 rpm Standard sizes 100 to 4 000 ml ASME Code stamp option Click here to view Product Information ZipperClave Stirred Laboratory Reactor Open this 500 to 4 000 ml high pressure laboratory reactor by hand A standard high pressure laboratory batch reactor Open seal without tools Pressure rating of 2 200 psig 151 bar Temperature rating 450 F 232 C O ring seals Magnetic mixer 3 300 rpm MagneDrive Standard sizes 500 to 4 000 ml Many equipment options Dispersimax impeller offered Click here to view Product Information Stirred Precontacting Pot Mix slurry catalysts and pwder into pressurized chemical reactions Add hard to wet powders into 1 gallon 4 Liters of high pressure viscous chemicals using a stirred jacketed reactor It is basic equipment for the slurry phase gas phase Spheripol polypropylene process The 1 000 psig 69 bar pressure rating 212 F 100 C allows direct injection of the mixture into a reaction under pressure The MagneDrive magnetically coupled mixer stirs viscous fluids Click here to view

    Original URL path: http://www.autoclaveengineers.com/products/stirred_reactor/index.html (2016-04-26)
    Open archived version from archive

  • Universal Reactor Controller - URC II
    pressure stirring speed and other parameters for laboratory style reactors FEATURES and BENEFITS Controls an electric heater 120 VAC or 240 VAC Internal 20 Amp Temperature Control Controls an electric motor 120 VAC handles a 90 VDC 1 2 hp motor 240 VAC handles a 180 VDC 1 2 hp motor 3 1 2 Diagonal Color Touchscreen user interface Two 2 Type K Thermocouples degree C or degree F readouts Non Latching overtemp control action Closed Loop DC motor speed control Pressure Indication Range up to 689 bar 10000 psi User adjustable in the field Extra analog input output for controlling a single Mass Flow Controller or Mass Flow Meter or an Analog Valve Non Latching overtemp control action RJ11 connector for RS232 communication the URC II comes with an adapter to adapt to 9 pin sub D CE marked UL CUL listed Can be used for all Parker Autoclave units from 25 ml to 4 000 ml volumes Pressure control and indication is set at the factory options are available contact factory for more information Bar psi pressure units Tachometer sensor input Pressure transducer input Two 2 digital 120 VAC or 240 VAC outputs to operate solenoid valves URC

    Original URL path: http://www.autoclaveengineers.com/products/process_instrumentation/urc2/index.html (2016-04-26)
    Open archived version from archive



  •