  • SC Hydraulic Engineering Corporation - AB-2 & AB-4 Air Booster Systems
    Request Form Air Booster Worksheet Gas Booster Worksheet Employment Opportunities General Applications Dimensions Ordering Modifications Performance Charts AB 2 AB 4 Air Booster Systems INCLUDES AIR DRIVE CONTROLS PRESSURES UP TO 555 PSI AB 4 LOW FLOW LOW PRESSURE APPLICATIONS EQUIPPED WITH ONE AB 2 OR AB 4 BOOSTER COMPACT AND LIGHTWEIGHT APPROX 35 LBS HIGH PRESSURE RECEIVER TO INCREASE FLOW CAPACITY The S10320 AB 2 and S10320 AB 4 Systems provide the most compact sized unit for air booster requirements Both units consist or either the 2 1 ratio or 4 1 ratio booster filter regulator combination with shut off and air pressure gauge 200 cubic inch reservoir tank with high pressure gauge The components are mounted on a sturdy free standing base and plate The complete system measures 18 1 4 high by 12 1 2 wide by 6 deep and weighs about 35 pounds This system is perfect for low flow cycling applications when a reserve of high pressure air up to 600 psi is required The reservoir allows the booster to build up pressure between cycles for higher flow ability than the booster can deliver alone Top off high pressure tires Increase plant air pressure Release spring actuated brakes Increase maximum torque on small air tools Increase marginal air pressure to valve actuators Extra force for small air clamps roll tensioners assembly machines and air presses MODEL SELECTION CHART Model No Maximum Rated Air Supply Ps Maximum Rated Air Outlet Po Connection Ports Static Outlet Stall Pressure Actual Area Ratio Displacement Per Stroke in3 per cycle Air Drive Air Inlet Air Outlet AB 2 150 psig 300 psig 1 4 NPT 1 4 NPT 2 Pa 2 01 2 9 10 3 bar 21 bar AB 4 150 psig 600 psig 1 4 NPT 1 4

    Original URL path: http://www.schydraulic.com/absystems.html (2016-04-26)
    Open archived version from archive


  • SC Hydraulic Engineering Corporation - ABD-2 Air Booster System
    Pressure Release Valves Services About Us Literature Contact Us Request a Quote Credit Card Form Distributor Section RMA Request Form Air Booster Worksheet Gas Booster Worksheet Employment Opportunities General Applications Dimensions Ordering Modifications Performance Charts ABD 2 Air Booster System PRESSURES UP TO 250 PSI INCLUDES AIR DRIVE CONTROLS WEIGHS APPROXIMATELY 145 LBS EQUIPPED WITH ONE ABD 2 BOOSTER HIGH FLOW LOW PRESSURE APPLICATIONS 15 GALLON ASME RECEIVER TO INCREASE FLOW CAPACITY The S10320 ABD 2 Air Booster System is built for high volume applications requiring up to 250 psi air reserve in a 15 gallon ASME receiver with our double acting 2 1 ratio air booster The booster and receiver is mounted on a heavy duty skid with forklift provisions and weighs approximately 145 pounds Installation is simple with a 3 4 NPT inlet to an inline filter and a 1 2 NPT outlet high pressure regulator The receiver is protected with a safety relief valve and has both receiver and regulator pressure gauges This system is a low cost solution when high pressure and relative high volumes of air is required in a pneumatic application Contact us or one of our authorized distributors for application or sizing assistance Increase plant air pressure Applications requiring higher flow Increase maximum torque on small air tools Increase marginal air pressure to valve actuators Extra force for small air clamps roll tensioners assembly machines and air presses MODEL SELECTION CHART Model No Maximum Rated Air Supply Ps Maximum Rated Air Outlet Po Connection Ports Static Outlet Stall Pressure Actual Area Ratio Displacement Per Stroke in3 per cycle Air Drive Air Inlet Air Outlet ABD 2 150 psig 300 psig 3 4 NPT 1 2 NPT 1 2 NPT Pa Ps 2 01 223 10 3 bar 21 bar How to Order Table

    Original URL path: http://www.schydraulic.com/abd-2systems.html (2016-04-26)
    Open archived version from archive

  • SC Hydraulic Engineering Corporation - ABD-5 Air Booster System
    FLOW HIGH PRESSURE APPLICATIONS PRESSURES UP TO 600 PSI INCLUDES AIR DRIVE CONTROLS WEIGHS APPROXIMATELY 85 LBS 5 GALLON ASME RECEIVER TO INCREASE FLOW CAPACITY The S10320 ABD 5 System combines the rugged 5 1 ratio single stage double acting booster with a 600 PSI ASME reservoir for high pressure applications needing a five gallon reserve The unit can be mounted either horizontally as shown or vertical on a wall or equipment structure The compete unit weighs approximately 85 pounds The system is ready for hook up to an air supply and includes an inlet filter regulator with shut off and gauge safety relief valve muffler high pressure regulator and high pressure reservoir and outlet pressure gauges The S10320 ABD 5 system can save money when requirements need up to a 600 PSI supply of air with reserve capacity Contact us or one of our authorized distributors for application or sizing assistance Applications requiring higher flow Increase plant air pressure Increase marginal air pressure to valve actuators Increase maximum torque on small air tools Extra force for small air clamps roll tensioners assembly machines and air presses MODEL SELECTION CHART Model No Maximum Rated Air Supply Ps Maximum Rated Air Outlet Po Connection Ports Static Outlet Stall Pressure Actual Area Ratio Displacement Per Stroke in3 per cycle Air Drive Air Inlet Air Outlet ABD 5 150 psig 855 psig 3 4 NPT 1 2 NPT 1 2 NPT 4 7 Pa Ps 4 7 1 28 2 10 3 bar 59 bar How to Order Table TABLE 1 Air Booster Series 1 ABD Single Stage Double Acting TABLE 2 Modification Blank No Modification M200 Refrigerant Recovery M201 No Inlet Outlet Plumbing M202 Remote Pilot M203 No Inlet Outlet Plumbing Remote Pilot M204 Cooling Jacket M205 Cooling Jacket Remote Pilot M206

    Original URL path: http://www.schydraulic.com/abd-5systems.html (2016-04-26)
    Open archived version from archive

  • SC Hydraulic Engineering Corporation - Gas Boosters & Systems
    laser cutting aircraft support equipment and injection molding GB D Series Single Stage Single Acting Double Head Gas Booster The GB D series is a single acting booster with a double head air drive section It is suitable for boosting relatively low flows at medium pressure ranges A double head air motor section allows the booster to reach considerably higher pressures than the GB series The GB D series is available in three pressure ratios 15 1 30 1 and 75 1 These boosters can boost pressures from as low as 50 psi up to nominal pressures of 15 000 psi The output flow can be as high as 15 SCFM depending on the model and operating conditions GBD Series Single Stage Double Acting Gas Booster SC Hydraulic GBD series gas boosters double the output flow of the GB series They are suitable for boosting relatively high flows at medium pressure ranges This series reaches higher pressures than the GB series by using gas supply pressures to assist the air drive section in generating the total drive force of the booster The GBD series is available in four pressure ratios 5 1 15 1 30 1 and 75 1 These boosters can boost pressures from as low as 25 psi up to nominal pressures of 12 000 psi depending on the model The output flow can be as high as 80 SCFM depending on the model and operating conditions GBD D Series Double Acting Double Head Gas Booster The GBD D series combines a double acting high pressure section with a double head air drive section It is one of the most powerful series of all our gas boosters offering relatively high flow at high pressure Similar to our GBD series the GBD D series uses the gas supply pressure to assist the air drive section in generating the total drive force of the booster The GBD D series is available in three pressure ratios 15 1 30 1 and 75 1 These boosters can boost pressures from as low as 50 psi up to nominal pressures of 21 000 psi The output flow can be as high as 60 SCFM depending on the model and operating conditions GBT Series Two Stage Double Acting Gas Booster The GBT series is a double acting booster that uses two different compression ratio stages A low compression ratio stage is connected to a higher compression ratio stage allowing this booster to achieve the highest pressure increment possible These boosters are ideal for maximizing the use of low pressure gas supply bottles This series is available in three different models each combining two stages of the following pressure ratios 15 1 30 1 and 75 1 These boosters can boost pressures from as low as 50 psi up to nominal pressures of 10 750 psi The output flow can be as high as 14 SCFM depending on the model and operating conditions GBT D Series Two Stage Double Acting Double Head Gas Booster The

    Original URL path: http://www.schydraulic.com/gasboosters.html (2016-04-26)
    Open archived version from archive

  • SC Hydraulic Engineering Corporation - Air Driven Gas Boosters
    used at low pressures e g welding the pressurized supply is easily piped and controlled to the point of use with simple valving However if the end use requires the gas under pressure the supply cylinder pressure cannot be utilized after it has fallen to the level of the end use pressure Therefore the gas remaining will be wasted unless it is boosted If the application requires a pressure greater than the common supply cylinder pressure a gas booster must be used Depending on the unit selected you can boost gas pressure from 25 psi and up to 25 000 psi SC gas boosters are suitable for other applications such as bottle filling from nitrogen generators and dewars hydrogas suspension systems automotive air gas storage systems aircraft slide chute gas storage sulfur hexafluoride SF6 transfer for arc suppression and insulation of circuit breakers commonly found in the utility industry breathing air for scuba diving gas injection molding etc In addition to our complete line of gas boosters SC also fabricates custom gas booster systems for individual applications These units are manufactured to customer specifications and can include filters gauges pilot switches panel controls tubular frames etc Contact your distributor or our sales department for more information Selecting the right booster for your application We could fill several pages of formulas tables and explanations of how to determine the best most economical booster for your application After plowing through all the information including types of gas decaying supply versus constant displacement factors volumetric efficiencies and compression ratios just to name a few you may still wonder if you are making the right choice At SC Hydraulic Engineering we have a better way CALL US Or better yet take a minute to read the glossary of terms below so you know the information we need then fill out the online Gas Booster Worksheet Please make sure to fill out the form completely as all the information is important We ll have an answer for you within a couple of hours with a selection of boosters fill times if required pricing delivery time and the name of your nearest distributor We figure you have better things to do with your time besides doing our job For the best service in the industry call SC Hydraulic Engineering Glossary of Terms Pa Air Drive Pressure Pressure from air gas compressor available at the booster to drive the unit If the pressure fluctuates the lowest pressure available is used to calculate the output gas pressure The Pa and in some selections along with the supply pressure will determine the maximum stall pressure of the booster Va Air Drive Flow Volume of air gas measured in SCFM standard cubic feet per minute available to drive the unit The volume of air gas determines the speed in which the booster will cycle and therefore the volume delivered from the outlet port The volume of outlet gas also determines the speed in which a vessel is filled to a

    Original URL path: http://www.schydraulic.com/gb&gbd&gbtgasboosters.html (2016-04-26)
    Open archived version from archive

  • SC Hydraulic Engineering Corporation - GB Series Gas Booster
    to higher outlet pressures than those maximum material rated outlet pressures shown on table Refer to Static Outlet Stall Pressure formula shown on table for example for gas booster model GBD 30 the formula is Static Outlet Stall Pressure 30 Pa Ps Maximum recommended air drive operating pressure 100 psi Maximum rated air drive pressure 150 psi only for static outlet stall pressure How to Order Table TABLE 1 Gas Booster Series 1 GB Single Stage TABLE 2 Modification Blank No Modification M402 Remote Pilot TABLE 3 Cylinder Modification Blank Single Head TABLE 4 Pressure Ratio Single or First Stage 5 GB 15 GB 30 GB 75 GB TABLE 5 Pressure Ratio Second Stage Blank N A on GB Series TABLE 6 Service Option Blank Standard 02 Oxygen Service H2 Hydrogen Service Notes 1 Do not fill gap on a two digit description GB Gas Booster Modifications M014 Counter Port This option provides a 5 8 18 UNF thread port on the air motor section of the pump for installing a mechanical cycle counter M402 Remote Pilot This option provides a 1 8 NPT female port for remotely controlling the start stop of the pump by connecting an external air signal to actuate the air cycling valve Model No Maximum Material Rated Gas Supply Pressure Ps Maximum Material Rated Gas Outlet Pressure Po A Inlet Port B Outlet Port Static Outlet Stall Pressure Minimum Inlet Gas Pressure Ps Displacement Per Stroke in3 per cycle GB 15 2 250 psig 2 250 psig 1 4 NPT 15 Pa 50 psig 3 5 bar 7 05 155 bar 155 bar 1 4 NPT GB 30 4 500 psig 4 500 psig 1 4 NPT 30 Pa 100 psig 7 bar 3 1 310 bar 310 bar 1 4 NPT GB 75 6 000 psig 11 250 psig 9 16 18 1 75 Pa 250 psig 17 bar 1 2 410 bar 775 bar 9 16 18 1 GB D30 6 000 9 000 1 4 NPT 60 Pa 200 psig 13 bar 3 1 410 bar 620 bar 1 4 NPT GB D75 6 000 20 000 psig 9 16 18 1 150 Pa 250 psig 17 bar 1 2 410 bar 1 380 bar 9 16 18 1 GBD 5 1500 psig 1500 1 2 NPT 4 7 Pa Ps 25 psig 28 2 103 bar 103 bar 1 2 NPT GBD 15 5 000 psig 5 000 psig 1 4 NPT 15 Pa Ps 50 psi 3 5 bar 14 1 345 bar 345 bar 1 4 NPT GBD 30 6 000 psig 9 000 psig 1 4 NPT 30 Pa Ps 100 psig 7 bar 6 3 410 bar 620 bar 1 4 NPT GBD 75 6 000 psig 20 000 psig 9 16 18 1 75 Pa Ps 250 psig 17 bar 2 4 410 bar 1 380 bar 9 16 18 1 GBD D15 5 000 psig 5 000 psig 1 4 NPT 30 Pa Ps 50

    Original URL path: http://www.schydraulic.com/gbgasboosters.html (2016-04-26)
    Open archived version from archive

  • SC Hydraulic Engineering Corporation - GB-D Series Gas Booster
    for example for gas booster model GBD 30 the formula is Static Outlet Stall Pressure 30 Pa Ps Maximum recommended air drive operating pressure 100 psi Maximum rated air drive pressure 150 psi only for static outlet stall pressure How to Order Table TABLE 1 Gas Booster Series 1 GB Single Stage TABLE 2 Modification Blank No Modification M402 Remote Pilot TABLE 3 Cylinder Modification D Double Head TABLE 4 Pressure Ratio Single or First Stage 15 GB 30 GB 75 GB TABLE 5 Pressure Ratio Second Stage Blank N A on GB D Series TABLE 6 Cylinder Modification Blank Standard 02 Oxygen Service H2 Hydrogen Service Notes 1 Do not fill gap on a two digit description GB D Gas Booster Modifications M014 Counter Port This option provides a 5 8 18 UNF thread port on the air motor section of the pump for installing a mechanical cycle counter M402 Remote Pilot This option provides a 1 8 NPT female port for remotely controlling the start stop of the pump by connecting an external air signal to actuate the air cycling valve Model No Maximum Material Rated Gas Supply Pressure Ps Maximum Material Rated Gas Outlet Pressure Po A Inlet Port B Outlet Port Static Outlet Stall Pressure Minimum Inlet Gas Pressure Ps Displacement Per Stroke in3 per cycle GB 15 2 250 psig 2 250 psig 1 4 NPT 15 Pa 50 psig 3 5 bar 7 05 155 bar 155 bar 1 4 NPT GB 30 4 500 psig 4 500 psig 1 4 NPT 30 Pa 100 psig 7 bar 3 1 310 bar 310 bar 1 4 NPT GB 75 6 000 psig 11 250 psig 9 16 18 1 75 Pa 250 psig 17 bar 1 2 410 bar 775 bar 9 16 18 1 GB D30 6 000 9 000 1 4 NPT 60 Pa 200 psig 13 bar 3 1 410 bar 620 bar 1 4 NPT GB D75 6 000 20 000 psig 9 16 18 1 150 Pa 250 psig 17 bar 1 2 410 bar 1 380 bar 9 16 18 1 GBD 5 1500 psig 1500 1 2 NPT 4 7 Pa Ps 25 psig 28 2 103 bar 103 bar 1 2 NPT GBD 15 5 000 psig 5 000 psig 1 4 NPT 15 Pa Ps 50 psi 3 5 bar 14 1 345 bar 345 bar 1 4 NPT GBD 30 6 000 psig 9 000 psig 1 4 NPT 30 Pa Ps 100 psig 7 bar 6 3 410 bar 620 bar 1 4 NPT GBD 75 6 000 psig 20 000 psig 9 16 18 1 75 Pa Ps 250 psig 17 bar 2 4 410 bar 1 380 bar 9 16 18 1 GBD D15 5 000 psig 5 000 psig 1 4 NPT 30 Pa Ps 50 psi 3 5 bar 14 1 345 bar 345 bar 1 4 NPT GBD D30 6 000 psig 9 000 psig 1 4 NPT

    Original URL path: http://www.schydraulic.com/gb-dgasboosters.html (2016-04-26)
    Open archived version from archive

  • SC Hydraulic Engineering Corporation - GBD Series Gas Booster
    pressures can be reached under special operating conditions Do not use air drive and or gas supply pressures that equate to higher outlet pressures than those maximum material rated outlet pressures shown on table Refer to Static Outlet Stall Pressure formula shown on table for example for gas booster model GBD 30 the formula is Static Outlet Stall Pressure 30 Pa Ps Maximum recommended air drive operating pressure 100 psi Maximum rated air drive pressure 150 psi only for static outlet stall pressure How to Order Table TABLE 1 Gas Booster Series 1 GBD Single Stage Double Acting TABLE 2 Modification Blank No Modification M401 No Inlet No Outlet Plumbing 2 M402 Remote Pilot M403 Plumbing for Single Inlet Outlet TABLE 3 Cylinder Modification Blank Single Head TABLE 4 Pressure Ratio Single or First Stage 5 GBD 15 GBD 30 GBD 75 GBD TABLE 5 Pressure Ratio Second Stage Blank N A on GBD Series TABLE 6 Service Option Blank Standard 02 Oxygen Service H2 Hydrogen Service Notes 1 Do not fill gap on a two digit description 2 Available on GBD 5 only GBD Gas Booster Modifications M014 Counter Port This option provides a 5 8 18 UNF thread port on the air motor section of the pump for installing a mechanical cycle counter M402 Remote Pilot This option provides a 1 8 NPT female port for remotely controlling the start stop of the pump by connecting an external air signal to actuate the air cycling valve Model No Maximum Material Rated Gas Supply Pressure Ps Maximum Material Rated Gas Outlet Pressure Po A Inlet Port B Outlet Port Static Outlet Stall Pressure Minimum Inlet Gas Pressure Ps Displacement Per Stroke in3 per cycle GB 15 2 250 psig 2 250 psig 1 4 NPT 15 Pa 50 psig 3 5 bar 7 05 155 bar 155 bar 1 4 NPT GB 30 4 500 psig 4 500 psig 1 4 NPT 30 Pa 100 psig 7 bar 3 1 310 bar 310 bar 1 4 NPT GB 75 6 000 psig 11 250 psig 9 16 18 1 75 Pa 250 psig 17 bar 1 2 410 bar 775 bar 9 16 18 1 GB D30 6 000 9 000 1 4 NPT 60 Pa 200 psig 13 bar 3 1 410 bar 620 bar 1 4 NPT GB D75 6 000 20 000 psig 9 16 18 1 150 Pa 250 psig 17 bar 1 2 410 bar 1 380 bar 9 16 18 1 GBD 5 1500 psig 1500 1 2 NPT 4 7 Pa Ps 25 psig 28 2 103 bar 103 bar 1 2 NPT GBD 15 5 000 psig 5 000 psig 1 4 NPT 15 Pa Ps 50 psi 3 5 bar 14 1 345 bar 345 bar 1 4 NPT GBD 30 6 000 psig 9 000 psig 1 4 NPT 30 Pa Ps 100 psig 7 bar 6 3 410 bar 620 bar 1 4 NPT GBD 75 6 000

    Original URL path: http://www.schydraulic.com/gbdgasboosters.html (2016-04-26)