  • Angles for LISST-100X VSF measurement in WATER | Sequoia Scientific
    0 120 0 110 8 25 0 240 283 0 260 0 120 0 141 0 130 9 24 0 283 0 334 0 307 0 141 0 167 0 154 10 23 0 334 0 394 0 362 0 167 0 197 0 181 11 22 0 394 0 465 0 428 0 197 0 232 0 214 12 21 0 465 0 548 0 505 0 232 0 274 0 252 13 20 0 548 0 647 0 596 0 274 0 324 0 298 14 19 0 647 0 764 0 703 0 324 0 382 0 351 15 18 0 764 0 901 0 829 0 382 0 451 0 415 16 17 0 901 1 063 0 979 0 451 0 532 0 489 17 16 1 063 1 255 1 155 0 532 0 627 0 578 18 15 1 255 1 481 1 363 0 627 0 740 0 682 19 14 1 481 1 747 1 609 0 740 0 874 0 804 20 13 1 747 2 062 1 898 0 874 1 031 0 949 21 12 2 062 2 433 2 240 1 031 1 217 1 120 22 11 2 433 2 871 2 643 1 217 1 436 1 322 23 10 2 871 3 389 3 119 1 436 1 694 1 560 24 9 3 389 3 999 3 681 1 694 1 999 1 841 25 8 3 999 4 719 4 344 1 999 2 359 2 172 26 7 4 719 5 568 5 126 2 359 2 784 2 563 27 6 5 568 6 571 6 049 2 784 3 286 3 025 28 5 6 571 7 754 7 138 3 286 3 877 3 569 29 4 7

    Original URL path: http://www.sequoiasci.com/article/angles-for-lisst-100x-vsf-measurement-in-water/ (2016-02-13)
    Open archived version from archive


  • Angles for LISST-100X VSF measurement in AIR | Sequoia Scientific
    0 159 0 147 8 25 0 319 0 376 0 346 0 159 0 188 0 173 9 24 0 376 0 444 0 409 0 188 0 222 0 204 10 23 0 444 0 524 0 482 0 222 0 262 0 241 11 22 0 524 0 618 0 569 0 262 0 309 0 284 12 21 0 618 0 729 0 671 0 309 0 365 0 336 13 20 0 729 0 861 0 792 0 365 0 430 0 396 14 19 0 861 1 02 0 935 0 430 0 508 0 467 15 18 1 02 1 20 1 10 0 508 0 599 0 552 16 17 1 20 1 41 1 30 0 599 0 707 0 651 17 16 1 41 1 67 1 54 0 707 0 834 0 768 18 15 1 67 1 97 1 81 0 834 0 985 0 906 19 14 1 97 2 32 2 14 0 985 1 16 1 07 20 13 2 32 2 74 2 52 1 16 1 37 1 26 21 12 2 74 3 24 2 98 1 37 1 62 1 49 22 11 3 24 3 82 3 52 1 62 1 91 1 76 23 10 3 82 4 51 4 15 1 91 2 25 2 07 24 9 4 51 5 32 4 90 2 25 2 66 2 45 25 8 5 32 6 28 5 78 2 66 3 14 2 89 26 7 6 28 7 41 6 82 3 14 3 70 3 41 27 6 7 41 8 74 8 05 3 70 4 37 4 02 28 5 8 74 10 31 9 49 4 37 5 16 4 75 29 4

    Original URL path: http://www.sequoiasci.com/article/angles-for-lisst-100x-vsf-measurement-in-air/ (2016-02-13)
    Open archived version from archive

  • LISST bin sizes | Sequoia Scientific
    05 1 89 3 48 4 11 3 78 10 44 12 32 11 35 6 67 7 70 7 17 4 2 05 2 42 2 23 4 11 4 85 4 46 12 32 14 54 13 39 7 70 8 89 8 27 5 2 42 2 86 2 63 4 85 5 72 5 27 14 54 17 16 15 80 8 89 10 27 9 55 6 2 86 3 38 3 11 5 72 6 75 6 21 17 16 20 25 18 64 10 27 11 86 11 03 7 3 38 3 98 3 67 6 75 7 97 7 33 20 25 23 90 22 00 11 86 13 69 12 74 8 3 98 4 70 4 33 7 97 9 40 8 65 23 90 28 20 25 96 13 69 15 81 14 71 9 4 70 5 55 5 11 9 40 11 09 10 21 28 20 33 28 30 64 15 81 18 26 16 99 10 5 55 6 55 6 03 11 09 13 09 12 05 33 28 39 28 36 16 18 26 21 08 19 62 11 6 55 7 72 7 11 13 09 15 45 14 22 39 28 46 35 42 67 21 08 24 35 22 66 12 7 72 9 12 8 39 15 45 18 23 16 78 46 35 54 69 50 35 24 35 28 12 26 16 13 9 12 10 76 9 90 18 23 21 51 19 81 54 69 64 54 59 42 28 12 32 47 30 21 14 10 76 12 69 11 69 21 51 25 39 23 37 64 54 76 17 70 11 32 47 37 49 34 89 15 12 69 14 98 13 79 25 39 29 96 27 58 76 17 89 88 82 74 37 49 43 30 40 29 16 14 98 17 68 16 27 29 96 35 36 32 55 89 88 106 07 97 64 43 30 50 00 46 53 17 17 68 20 86 19 20 35 36 41 72 38 41 106 07 125 17 115 22 50 00 57 74 53 73 18 20 86 24 62 22 66 41 72 49 23 45 32 125 17 147 70 135 97 57 74 66 68 62 05 19 24 62 29 05 26 74 49 23 58 10 53 48 147 70 174 30 160 45 66 68 77 00 71 65 20 29 05 34 28 31 56 58 10 68 56 63 11 174 30 205 69 189 34 77 00 88 91 82 74 21 34 28 40 45 37 24 68 56 80 91 74 48 205 69 242 72 223 44 88 91 102 68 95 55 22 40 45 47 74 43 95 80 91 95 48 87 89 242 72 286 43 263 67 102 68 118 57 110 34 23 47 74 56

    Original URL path: http://www.sequoiasci.com/article/lisst-bin-sizes/ (2016-02-13)
    Open archived version from archive

  • Articles | Sequoia Scientific
    theory phase function and LISST 100X measurement Sequoia May 30 2008 The following data were acquired on 20 July 2006 and selected randomly for a comparison with Mie theory Phase function calculations from the LISST 100X data follow Operating principle of the LISST 25 constant calibration sediment sensor LISST 25X Figure 1 From left to right a laser collimating lens scattering particles receiving lens and the scattered light on a detector Figure 2 The laser lenses and the detector The lower half of the detector is comet shaped Figure 3 The ratio of estimated to true concentration against Processing LISST 100 and LISST 100X data in MATLAB Sequoia April 30 2008 I INTRODUCTION II SOFTWARE FUNCTIONS II 1 Using the invert p processing file II 2 Using Matlab functions for detailed processing Loading your files Viewing the raw data files Viewing partial results with one command Performing the inversion Computing tt2mat m TT2MAT M Sequoia April 29 2008 This article contains the code for the tt2mat m Matlab script used for reading the binary dat files from LISST 100 LISST 100X LISST Portable and LISST Infinite To use copy all lines between the into your Matlab editor getscat m GETSCAT M Sequoia April 29 2008 This article contains the source code for the getscat m file that is used to obtain raw scattering data from a LISST 100 or LISST 100X dat file To use copy and paste all text between the into the Matlab editor and save Matlab processing of LISST ST data MATLAB processing of LISST ST data Sequoia April 18 2008 this article is based on Application Note L011 The LISST ST is programmed to store data from many successive settling experiments Each settling experiment by default lasts one full day though the length of the experiment

    Original URL path: http://www.sequoiasci.com/library/articles/page/7/ (2016-02-13)
    Open archived version from archive

  • LISST-100X | Categories | Sequoia Scientific
    about the data quality of my LISST 100 or LISST 100X data can you advise me January 13 2010 I m not sure about the quality of my LISST 100 or LISST 100X data can you advise me Sequoia January 13 2010 Q I think that I have a problem with my data and or my data processing and would like you to have a look Read more Could Not Find Instrumentxxxx section in LISST ini January 13 2010 Could Not Find Instrumentxxxx Section in LISST INI Sequoia January 13 2010 Q When I try to program the instrument I get this error note Instrument1335 will change depending on the serial number of your instrument A Go Read more I Cannot Offload Data From my LISST 100X January 13 2010 I Cannot Offload Data From my LISST 100X Sequoia January 13 2010 Q When I try to offload the data from my LISST 100X I get an error and the offload stops I can talk to the instrument and program it but it will not offload A Read more Angles for LISST 100X VSF measurement in WATER November 25 2009 Angles for LISST 100X VSF measurement in WATER Sequoia November 25 2009 The table shows the angles in Degrees for the LISST 100 or LISST 100X VSF measurement in WATER For the angles IN AIR click here Type B Type C Ring Read more Previous Next More in About About Suspended Sediment Concentration and Particle Sizing Methods Course Staff News PiE Conference 2014 PiE Conference 2014 Customer List Newsletter Contact International Distributors Our Newsletter Sign up to get the latest news on Sequoia and our products Home Products Product Overview LISST Instruments LISST 100X LISST ABS LISST Portable XR LISST Holo LISST Deep LISST StreamSide LISST STX LISST Hydro LISST

    Original URL path: http://www.sequoiasci.com/article_category/lisst-100x/page/6/ (2016-02-13)
    Open archived version from archive

  • How do I determine if my LISST-100 or LISST-ST can be upgraded to a LISST-100X or LISST-STX? | Sequoia Scientific
    to determine if your LISST 100 LISST ST can be upgraded Sequoia May 28 2010 SEQUOIA NO LONGER OFFERS LISST 100 OR LISST ST UPGRADES HOWEVER SEQUOIA WILL ACCEPT TRADE INS OF LISST 100 AND LISST ST MODELS WHICH WILL BE REPLACED WITH A NEW LISST 100X OR LISST STX AT A MUCH REDUCED PRICE CONTACT YOUR LOCAL DISTRIBUTOR FOR PRICING INFO Sequoia stopped building the LISST 100 and the LISST ST in March 2004 more than 6 years ago Those models were replaced by the LISST 100X and the LISST STX Due to the number of new instrument developments since then as well as the fact that we no longer can get electronics spare parts for the LISST 100 and LISST ST we will discontinue most of our support for the LISST 100 and LISST ST starting 01 01 2011 We do this so that we can better support the existing instrument models as well as new instrument developments Consequently as of 1 1 2011 only the following support will be available for the LISST 100 and LISST ST 1 Batteries will be available for purchase 2 Users will still be able to get help with data analysis data quality control etc to the same extent that they have always had Updated 11 21 2011 Questions to this news item Email us More in About About Suspended Sediment Concentration and Particle Sizing Methods Course Staff News PiE Conference 2014 PiE Conference 2014 Customer List Newsletter Contact International Distributors Categories General News Press Releases Our Newsletter Sign up to get the latest news on Sequoia and our products Home Products Product Overview LISST Instruments LISST 100X LISST ABS LISST Portable XR LISST Holo LISST Deep LISST StreamSide LISST STX LISST Hydro LISST Infinite LISST VSF LISST STOKES Optical VSF Sensors

    Original URL path: http://www.sequoiasci.com/about/news/how-do-i-determine-if-my-lisst-100-or-lisst-st-can-be-upgraded-to-a-lisst-100x-or-lisst-stx/ (2016-02-13)
    Open archived version from archive

  • Support for LISST-100 and LISST-ST to be discontinued 01/01/2011 | Sequoia Scientific
    100X and the LISST STX Due to the number of new instrument developments since then as well as the fact that electronics spare parts are no longer available for the LISST 100 and LISST ST Sequoia will discontinue most of the existing support for the LISST 100 and LISST ST starting 01 01 2011 We do this so that we can better support the existing instrument models as well as new instrument developments Consequently as of 1 1 2011 only the following support will be available for the LISST 100 and LISST ST 1 Batteries will be available for purchase 2 Users will still be able to get help with data analysis data quality control etc to the same extent that they have always had No other support services or repairs of any kind will be offered for the LISST 100 and LISST ST from 1 1 2011 If you are in doubt as to what kind of instrument you have look up the InstrumentData txt file This file resides in the same folder as the lisst exe file typically C Program FilesSequoiaLISST100 Open up the file in note pad and look for an X as the 5th value in that file In the example below sn 1219 is a LISST 100X whereas sn 1134 is a LISST 100 as there is no X in the InstrumentaData txt file 1219 c 529000 36000 X 1134 C 529000 27848 Questions about this press release Email Sales Marketing Manager Ole Mikkelsen More in About About Suspended Sediment Concentration and Particle Sizing Methods Course Staff News PiE Conference 2014 PiE Conference 2014 Customer List Newsletter Contact International Distributors Categories General News Press Releases Our Newsletter Sign up to get the latest news on Sequoia and our products Home Products Product Overview LISST Instruments

    Original URL path: http://www.sequoiasci.com/about/news/support-for-lisst-100-and-lisst-st-to-be-discontinued-01012011/ (2016-02-13)
    Open archived version from archive

  • EPA requires the use of LISSTs when using oil dispersants in the Gulf of Mexico | Sequoia Scientific
    LISSTs when using oil dispersants in the Gulf of Mexico May 21 2010 EPA requires the use of LISSTs when oil dispersants are applied Sequoia May 21 2010 The Environmental Protection Agency EPA has directed the use of LISST s in connection with the use of oil dispersants in the Gulf of Mexico in order to monitor the oil droplet size in situ What monitoring does the EPA currently require regarding the subsea application of dispersants Why is oil droplet size measured How is oil droplet size measured Read EPA s directive here with an addenum here More in About About Suspended Sediment Concentration and Particle Sizing Methods Course Staff News PiE Conference 2014 PiE Conference 2014 Customer List Newsletter Contact International Distributors Categories General News Press Releases Our Newsletter Sign up to get the latest news on Sequoia and our products Home Products Product Overview LISST Instruments LISST 100X LISST ABS LISST Portable XR LISST Holo LISST Deep LISST StreamSide LISST STX LISST Hydro LISST Infinite LISST VSF LISST STOKES Optical VSF Sensors LISST SL LISST 25X FlowControl Instruments FlowControl Lab FlowControl Sub Radiative Transfer Models EcoLight S HydroLight Accessories How to Buy Request a Quote Terms Of Sale

    Original URL path: http://www.sequoiasci.com/about/news/epa-requires-the-use-of-lissts-when-using-oil-dispersants-in-the-gulf-of-mexico/ (2016-02-13)
    Open archived version from archive



  •