  • Pump Stations Go Viral
    housed pardon the pun behind the domestic facade In reality the structure functions as an ordinary booster station for potable water albeit a cleverly designed neighborhood friendly one It s a story that seems to be trending and not just on the Internet Pump Housing Market On The Rise Since discovering The House On Wade Avenue which has actually been in existence since the late 70s I ve noticed some even more impressive that is less noticeable pump station houses Who would suspect that the bungalow pictured below is a stormwater pump station Photo courtesy of McKim Creed Inc The Alline Avenue pump station in Tampa FL was built out of necessity particularly to remedy street flooding but it represents the city s first attempt to have infrastructure blend in with residential surroundings The ribbon was cut on the 4 8 million 35 MGD facility in January 2013 and it has since won the Award of Outstanding Contribution to the Community from the Hillsborough Planning Commission it was the nearby Hillsborough Bay that would routinely flood the area Designed by McKim Creed engineers the pump station collection system is facilitated by three submersible 90 HP pumps two operating one standby hidden in the backyard as well as two nutrient removal baffle boxes positioned upstream for total suspended solids TSS reduction Downstream a dissipation box and box culvert are utilized to reduce flow velocity to less than 2 ft second entering the Hillsborough Bay thereby protecting sensitive vegetation and marine life As unsightly as a typical pump station is a glut of metal blocks and pipes the sewage pump station has to be the most unwelcome of neighbors for obvious reasons The Locust Valley Pump Station however has true curbside appeal a far cry from the utilitarian interior Photos courtesy of

    Original URL path: http://www.wateronline.com/doc/pump-stations-go-viral-0001 (2016-02-14)
    Open archived version from archive


  • 5 Steps Every Water Utility Should Take Now To Prepare For Disaster
    to see what they need But without clean water that hospital is not going to be able to maintain normal operations at all The EPA and other organizations are currently working to educate emergency response organizations on the importance of making water utilities a top priority But it is also important that each water utility take initiative prior to a weather emergency to prepare and protect itself Here are five critical steps every water utility should take before disaster strikes 1 Lobby For Emergency Support In every community there are local and state emergency planning committees Water utilities should not only have up to date contact information for these organizations but they should contact them now and begin to establish a relationship said Travers Contact information for emergency response teams can be found on the FEMA s Community Emergency Response Team CERT website At the local level water utilities need to set up clear lines of communication with city police and fire departments Utilities need to communicate in detail what they may need during an emergency A water emergency document released by the EPA recommends that utilities notify law enforcement and local emergency response teams that water staff may have to remain onsite and could be trapped at the plant during an emergency and should be checked in on Contacts should also be established locally to request emergency water supply if necessary Water sector employees should also communicate with emergency response teams about what kind of assistance they can provide to the response teams and the community as a whole during an emergency At the state level multiple water utilities may need to work together for change recommended Travers We would want the utilities to let these emergency response organizations know that the water sector needs to be a priority he said Utilities really need to lobby for representation in discussions about how statewide emergencies should be handled to include their needs 2 Evaluate Infrastructure Equipment And Supplies Now is the time to make sure everything inside and outside the plant can survive a major weather emergency Pump and lift stations in particular can be impacted by a weather event Emergency power systems should be in place at all critical stations explained Travers Flooding can threaten a pump or lift station If a pump station or lift station is in an anticipated flooding area there are ways to harden that facility by elevating it or ensuring the pumps can operate underwater said Travers Make sure electrical components of that station are safeguarded We ve had utilities that have constructed walls around their system to keep water out Regularly test backup lights generators backup chemical feeders and all pumps and motors It is also important to verify that spare pumps motors and other necessary spare parts are available Emergency electrical generators can be a big help but they should not be stored in flood prone areas of the facility Dry chemicals should always be stored off the floor in a dry

    Original URL path: http://www.wateronline.com/doc/steps-every-water-utility-should-take-now-to-prepare-for-disaster-0001 (2016-02-14)
    Open archived version from archive

  • Addressing Chronic Flooding In El Paso TX
    Water All Source Water Contamination Desalination Water Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Case Study June 18 2015 Addressing Chronic Flooding In El Paso TX Source Flygt A Xylem Brand The city of El Paso TX lies on the tip of the Chihuahuan desert and it is not uncommon for a year s worth of rain to occur in a matter of days during the summer These rain events have caused serious damage throughout the city for years and the flooding has always been particularly bad in the historic district With Flygt s assistance a new pump station was developed with a pumping capacity of 27 000 gallons per minute GPM By utilizing siphoning methods the city was able to accommodate the large swing in river elevations allowing the station to operate at both high and low river levels Image credit Dallas Floods Leah Biernacki 2015 used under an Attribution 2 0 Generic license

    Original URL path: http://www.wateronline.com/doc/addressing-chronic-flooding-in-el-paso-tx-0001 (2016-02-14)
    Open archived version from archive

  • Pump Station Monitoring White Papers and Case Studies Documents on Water Online
    maintenance visits and corresponding unbudgeted repair bills for the pumps at the township s main pump station Pump Station s Non Dispersibles Problem Solved 9 17 2015 Sun City AZ has had the same wastewater treatment plant since the 70s along with a new expensive problem non dispersible waste Monsters Protect Pump Station Weather Storms In Scotland 7 14 2015 Pump blockages and rags are a significant barrier to energy and operational efficiencies at pump stations causing unscheduled shut downs safety hazards for operators costly equipment repairs and increased power usage due to a decrease in the pumps hydraulic performance Scottish Water observed these negative effects caused by an influx of wipes and rags throughout a network of area pump stations Engineers looked to a proven powerful solution in the form of two JWC Environmental Channel Monster grinders at one of their most problematic sites Lift Station Upgraded After Rainstorm Causes Flood And Electrical Short 7 13 2015 Read the full case study to learn how the installation of the three Flygt horizontally mounted dry pit flood proof NZ 3171 submersible clog free pumps immediately offered a 25 percent boost in efficiency at a lift station in Manitoba Canada after a motor had shorted out due to excessive moisture and could not be replaced Robertson County Water Supply Corporation Adopts VTScada Software 7 10 2015 Serving just over 16 000 residents in eastern Texas the Robertson County Water Supply Corporation RCWSC operates a small rural water system with five water plants four wells one booster pump station and approximately 350 miles of PVC pipe In December of 2014 their systems integrator Express Electric recommended that they adopt VTScada software from Trihedral to remotely monitor and control their plants Sulzer Pumps Reduce Downtime At Water Utility 6 26 2015 Winslow Township

    Original URL path: http://www.wateronline.com/hub/bucket/pump-station-monitoring-white-papers-and-case-studies (2016-02-14)
    Open archived version from archive

  • Flygt ENM-10 Liquid Level Regulators Brochure
    Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Product Service Flygt ENM 10 Liquid Level Regulators Source Flygt A Xylem Brand Proper level regulation is critical for operational reliability Lack of proper regulation can cause improper operation pump damage or in the worst case overflow that results in environmental and economic consequences With over a decade of experience and countless satisfied users the natural choice for level regulation is the Flygt ENM 10 Contact The Supplier Click Here To Download Flygt ENM 10 Liquid Level Regulators Brochure Simple reliable and effective The Flygt ENM 10 level regulators are the ideal choice for most level control applications such as wastewater pumping stations and ground water or drainage pumping When the liquid level reaches the regulator the bulb tilts activating the internal microswitch which starts or stops a pump or triggers an alarm device Practically maintenance free The outer casing of Flygt ENM 10 level regulators are resistant to most aggressive liquids The cable material prevents buildup of deposits and other impurities Rather than floating on the surface ENM 10 hangs immersed in the liquid This prevents the cables from tangling when several regulators are used Xylem testing indicates Flygt ENM 10 level regulators last several times longer than most standard level regulators This ensures reliable operation and a low degree of maintenance thereby keeping service costs down to a minimum over the life cycle Environmentally friendly The Flygt ENM 10 level regulator contains no harmful or toxic materials such as lead or mercury and does not require the use of any adhesives All plastic components are welded and screwed together Need More Information Just Ask Click the button below to

    Original URL path: http://www.wateronline.com/doc/flygt-enm-liquid-level-regulators-0001 (2016-02-14)
    Open archived version from archive

  • Flygt SmartRun
    Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Product Service Flygt SmartRun Source Flygt A Xylem Brand Introducing SmartRun a pump controller solution for pump stations with up to three alternating pumps An integral part of the Flygt Experior concept this pump control unit lets your pump take care of itself freeing the pump station from debris setting the optimal speed for energy efficiency and cost savings as well as communicating with external monitoring equipment for peace of mind SmartRun handles pump cleaning pipe cleaning sump cleaning soft starts and stops giving you to a new level of reliability and efficiency in an easy to install solution The integrated intelligence and variable speed control mean it s the perfect match for Flygt N pumps a combination that can potentially reach energy savings up to 50 Contact The Supplier Click Here To Download Flygt SmartRun Brochure Unplanned downtime costs money With SmartRun installed an abnormal blockage triggers a cleaning cycle optimized for the N impeller rotating it back and forth to release the debris SmartRun s high starting torque equivalent to direct online ensures a reliable start in tough wastewater conditions Pre programmed start and stop ramps enable smoother and more gentle running of the pump reducing wear and tear of the valves and increasing the lifetime of the pump It ll even clean the pipes SmartRun regularly performs one pump down at full speed flushing the pipes properly Following that it will carry out sump cleaning pumping down the water to snoring level removing floating debris and reducing sedimentation Need More Information Just Ask Click the button below to directly contact the supplier Use

    Original URL path: http://www.wateronline.com/doc/flygt-smartrun-0002 (2016-02-14)
    Open archived version from archive

  • QUICKSMART System Controls
    Labor Resiliency SCADA Automation Source Water All Source Water Contamination Desalination Water Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Product Service QUICKSMART System Controls Source Smith Loveless Inc Smith Loveless new QUICKSMART System Controls provide monitoring and adjustment abilities for a variety of pump station functions in one single easy to use touch screen control system The redesigned application layout simplifies control modification screen navigation and viewing of system status with screen function buttons and a status bar accessible from each screen Features added to the new controls include a maintenance log feature which displays periodic recommended operation and maintenance instructions and makes lubrication suggestions based on actual pump run times and an I O Status screen that displays controller digital and analog I O status QUICKSMART System Controls also offers significant help and troubleshooting support and a Spanish language option The 7 65K Color TFT LCD Touch Screen HMI controller is UL listed NEMA 4 Rated when installed in an enclosure and is protected by a surge protective device SPD and a 5 year pro rated warranty Contact The Supplier Click Here To Download QUICKSMART System Controls Brochure Main Features PLC Station Control Alarm Management Wet Well Level Simulation Prime Mode Selection Help Troubleshooting Info Graphical Pump Notifications English Spanish Languages Need More Information Just Ask Click the button below to directly contact the supplier Use it to Ask a question Request more detailed information or literature Discuss your current project application Request a quote Locate a distributor in your area Schedule a demo

    Original URL path: http://www.wateronline.com/doc/quicksmart-system-controls-0001 (2016-02-14)
    Open archived version from archive

  • John Meunier Cont-Flo CF Vertical Bar Screen
    Water Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Product Service John Meunier Cont Flo CF Vertical Bar Screen Source Veolia Water Technologies Screenings removal is an essential component of efficient headworks design Removing undesirable inorganic material from the raw influent greatly reduces wear and O M requirements in the downstream processes These criteria are successfully met with the very efficient and robust Cont Flo Bar Screen With over 800 units already in operation the heavy duty Cont Flo has repeatedly proven its ability to provide simple long lasting service in wastewater pump station and stormwater applications With over 800 installations worldwide the Cont Flo Bar Screen is a proven reliable component of John Meunier pretreatment products Contact The Supplier Click Here To Download Cont Flo Type CF Vertical Bar Screen Brochure Features of the CONT FLO Screen widths available from 14 to 96 355 to 2445 mm Screen depth available up to 80 24 4 m channel invert to discharge Bar rack spacing available from 7 16 to 3 11 to 75 mm Offered in painted galvanized carbon or stainless steel construction All maintenance performed from operating floor Vertical structure reduces space requirements limits civil cost and allows for easy retrofit Versatile screen well suited to wastewater pump station and stormwater applications John Meunier products superior application engineering support and service Need More Information Just Ask Click the button below to directly contact the supplier Use it to Ask a question Request more detailed information or literature Discuss your current project application Request a quote

    Original URL path: http://www.wateronline.com/doc/john-meunier-cont-flo-cf-vertical-bar-screen-0001 (2016-02-14)
    Open archived version from archive



  •