archive-com.com » COM » W » WATERONLINE.COM

Total: 1905

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • The Advantages Of Pressure Sewer Systems Vs Gravity-Fed Systems
    network in rocky hilly coastal or other difficult areas such as those with high water tables where conventional gravity fed sewers would be too costly A PSS offers the freedom to build and develop wherever the need exists even in areas that were once off limits or those with only a low population but who must nevertheless be provided with a reliable and efficient solution An effective PSS will also address environmental concerns that surround many of today s new developments Their low impact construction characteristics minimize disruption to the local environment during installation while their comparatively small footprint means less vegetation removal The better systems are also completely sealed which eliminates the opportunity for any sewage or contaminated liquid to leak into the surrounding area Odor issues are therefore dramatically reduced by a PSS and most systems are also perfectly compatible with effluent re use schemes Operator Advantages A PSS offers a host of other benefits too not least the fact that it needs absolutely no input from the property owners it serves This effectively makes a good PSS invisible to the end user but there are also many benefits for the network operator Prominent among these is the intelligent operation capability which some systems can provide The ability to monitor the performance of the network performance often remotely via the web and capture performance data allows various parameters to be managed so that the system operates at peak efficiency Operating periods can be programmed and staggered so that peak loads on the wider network are reduced This feature can also help reduce or eliminate the emergency storage capacity which the network s sewage pump station might otherwise require to cope with input surges This remote monitoring capability also allows for the early detection of problems in the network so that immediate action can be taken before matters escalate thus reducing maintenance costs and network disruption With some of the better PSS options available their intelligent operation capability also includes the ability to program software upgrades and run self diagnostic tests Their control network and two way telemetry features allow multiple individual units to be linked and managed from a centralized network point Maintaining Safety Routine maintenance requirements are also catered for by efficient system designs One system on the market even offers completely clean access to the motor which sits in a dry well as opposed to being submersed in sewage in the conventional manner This keeps the motor and electrical systems separate from the fluid being pumped and so makes maintenance a far quicker safer and more pleasant process It also ensures that unlike many alternative systems there is no need to work in unpleasant and confined spaces The robust nature of some of today s grinder units also creates a zero planned maintenance requirement which eases the task of maintenance even further Safety is another area where a modern PSS can offer considerable advantages Some now include various smart safeguards which greatly reduce the possibility of

    Original URL path: http://www.wateronline.com/doc/the-advantages-of-pressure-sewer-systems-vs-gravity-fed-systems-0001 (2016-02-14)
    Open archived version from archive


  • Sewers and Sewer Line Maintenance Documents on Water Online
    in more ways than one instituting the largest and most innovative infrastructure project in the city s history Making The Grade A Six Point Plan To Regain America s Infrastructure Leadership 3 31 2015 What will it take to get the country s infrastructure back on track and up to speed A group of experts has set the course WWEMA Window Buy American March To The Sea 1 21 2015 Many of you may have grown up in the decades where your perfectly reasonable teenage parental ask was met with the story of lemmings blindly following their leader over the cliff to their death at sea Busted Pipes D C Demonstrates The Rule Not The Exception 1 5 2015 Commuters in Washington D C woke up recently to an abundance of water While this hardly seems problematic to those in parts of the world that grapple with drought contamination and other water safety issues water is only beneficial when it arrives to the right place at the right time and safe for consumption The Advantages Of Pressure Sewer Systems Vs Gravity Fed Systems 12 1 2014 As pressure increases to develop and expand our cities and communities the need to build on areas previously deemed as unsuitable grows accordingly Top 10 Tweets On Flushables 10 31 2014 With the immense interest that we re noticing on the issue of flushables or what not to flush to avoid havoc in wastewater collection systems Water Online decided to dip our toe into some new waters We recently hosted our first Twitter party or hashtag chat or whatever the kids are calling them these days and I m happy to report some very positive outcomes How To Avoid Sewer Stench And Corrosion 7 31 2014 You might think sewer stench should be expected

    Original URL path: http://www.wateronline.com/hub/bucket/sewers-and-sewer-line-maintenance (2016-02-14)
    Open archived version from archive

  • Pipe Repair Emergency Response In Compton
    approximately 1 400 miles of sewers that range in size from eight to 144 inches in diameter They convey approximately 500 million gallons per day of wastewater to 11 wastewater treatment plants Maintaining this enormous system is an ongoing challenge Curves that were not able to push through were relined by open cut LACSD has been actively repairing sections of Joint Outfall G since 2009 with several phases previously rehabbed The next phase of rehab was scheduled for an October 2013 start up in Compton The existing Joint Outfall G Unit 9 is a 39 inch clay tile lined RCP pipe that was installed in the 1940 s along the current Interstate 710 Freeway which connects Pasadena to Long Beach The freeway was built in the 70 s and pipe had to be relocated to allow for this work In the late 90 s it was observed that the cast in place clay tiles were falling due to corrosion in the mortar seal filling the gap between these tiles Ultimately the tiles in the top half were lost and RCP was exposed to severe hydrogen sulfide corrosion The contractor on the most recent section JO G Colich and Sons LP of Gardena California had to rehab several junction structures One of them was located in the intersection of Atlantic Street and Greenleaf Road During excavation around the structure the contractor exposed the 39 inch RCP sewer on the downstream end and found a short section of missing pipe crown The upstream 39 inch RCP sewer was previously sliplined with Hobas 33 inch FRP and the downstream pipe was scheduled to be rehabilitated in the near future After CCTV inspection it was determined that approximately 700 feet of sewer downstream of Manhole 847 was deteriorated and needed urgent repair This emergency repair work was completed as a change order to the existing project stated Derek K Zondervan P E Civil Engineer Sewer Design Section for LACSD Lightweight pipes were easily handled onsite even with limited workspace In order to rehabilitate the deteriorated pipe Hobas supplied 660 feet of 33 inch diameter flush joint pipe in 20 foot lengths and 60 feet of the same diameter in five foot lengths The short pipes were required due to the presence of curves in the existing line The reach included two short radius curves one with a deflection of approximately four degrees near the downstream end of the 700 foot reach and a second with a deflection of approximately 25 degrees just downstream of Manhole 847 within the insertion pit Five foot sticks of Hobas pipe were pushed through the four degree curve and the 25 degree curve was lined by open cut said Zondervan Sliplining the existing 39 inch RCP with 33 inch FRP pipe was the preferred option because it avoided the need for a full above ground flow bypass said Zondervan Another reason that Hobas was chosen was the quick response from the pipe manufacturer Hobas was able to provide the

    Original URL path: http://www.wateronline.com/doc/pipe-repair-emergency-response-in-compton-0001 (2016-02-14)
    Open archived version from archive

  • How To Remove FOG Deposits And Prevent Sewer Overflow
    Line Maintenance Stormwater Regulations and Legislation Industrial Food Beverage Petroleum Refining All Petroleum Refining Produced Water Power Generation Water Reuse Utility Management AMR AMI and Metering Asset Management Consumer Outreach Funding Labor Resiliency SCADA Automation Source Water All Source Water Contamination Desalination Water Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers White Paper January 14 2014 How To Remove FOG Deposits And Prevent Sewer Overflow Source DO2E Fats oils and grease FOG deposits present a problem for the wastewater industry as they create sewer lines blockages that lead to overflow Digester systems can successfully remove these deposits with the latest environmentally friendly technology by breaking them down into microparticulates This paper offers a technical review of the solutions available for applications such as commercial and residential lift stations grease traps and wet wells Newsletter Signup SIGN ME UP YOU MAY ALSO LIKE Contact Details Company Name DO2E Address 9657 Stagecoach Commercial Park Circle Suite A Spanish

    Original URL path: http://www.wateronline.com/doc/how-to-remove-fog-deposits-and-prevent-sewer-overflow-0001 (2016-02-14)
    Open archived version from archive

  • Sewers & Sewer Line Maintenance White Papers & Case Studies Documents on Water Online
    Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Sewers Sewer Line Maintenance White Papers Case Studies AMERICAN s Versatility Shines In Rocky Terrain 4 9 2015 Murfreesboro Tennessee is the fastest growing city in Tennessee and one of the fastest growing cities in the United States with its population more than doubling since 2000 N Pumps Resolve Clogging Issues And Control Maintenance Costs 3 24 2015 A public works director in southern Kalamazoo MI recommended the county investigate new generation Flygt brand pumps for five troublesome singlephase stations along their system Pipe Repair On A Budget 3 7 2014 A new pipe repair solution promises to save time and money while also being sustainable long lasting fully scalable and safe for workers Pipe Repair Emergency Response In Compton 2 19 2014 When the Sanitation Districts of Los Angeles County LACSD were formed in the 1920s the agency embarked on its first major project the construction of the backbone trunk sewer of the Joint Outfall System JOS Since then the Sanitation Districts have completed many challenging projects providing environmentally sound cost effective wastewater and solid waste management services to over five million people in Los Angeles County How To Remove FOG Deposits And Prevent Sewer Overflow 1 14 2014 Fats oils and grease FOG deposits present a problem for the wastewater industry as they create sewer lines blockages that lead to overflow Digester systems can successfully remove these deposits with the latest environmentally friendly technology by breaking them down into microparticulates This paper offers a technical review

    Original URL path: http://www.wateronline.com/hub/bucket/sewers-sewer-line-maintenance-white-papers-case-studies (2016-02-14)
    Open archived version from archive

  • Hydro-Guard HG-8 Automatic Flushing System
    Funding Labor Resiliency SCADA Automation Source Water All Source Water Contamination Desalination Water Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Product Service Hydro Guard HG 8 Automatic Flushing System Source Mueller Co Designed to increase chlorine residual consistency in potable water systems Mueller has added the HG 8 model to the expanding line of Hydro Guard Automatic Flushing Systems Hydro Guard HG 8 is installed below the frost line with all components easily accessible from the ground surface in the Mueller Thermal Coil Box Dechlorinated discharge water is directed to the storm water drainage system or local retention pond In addition the product is designed to accept a 1 inch meter Contact The Supplier Click Here To Download Hydro Guard HG 8 Automatic Flushing System Datasheet Benefits of flushing with the HG 8 Standard Sub surface System Reduces water waste associated with flushing Improves capability to meet EPA Stage II DBPR Standards Controlled and consistent flushing of distribution system Enhance success in maintaining consistent residual levels Reduced operational expenses i e labor vehicle maintenance and benefits costs Engineered for durability and long service life helps to maximize Life Cycle Cost benefits Meter easily added to track non revenue water Find a Mueller Distributor Near You Need More Information Just Ask Click the button below to directly contact the supplier Use it to Ask a question Request more detailed information or literature Discuss your current project application Request a quote Locate a distributor in your area Schedule a demo Contact The Supplier Mueller Co Contact The

    Original URL path: http://www.wateronline.com/doc/hydro-guard-hg-automatic-flushing-system-0001 (2016-02-14)
    Open archived version from archive

  • Mighty Mike Maintenance Tablets
    and Legislation Industrial Food Beverage Petroleum Refining All Petroleum Refining Produced Water Power Generation Water Reuse Utility Management AMR AMI and Metering Asset Management Consumer Outreach Funding Labor Resiliency SCADA Automation Source Water All Source Water Contamination Desalination Water Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Product Service Mighty Mike Maintenance Tablets Source Bio Microbics Inc Maintain your drain with Mighty Mike specialty tablets and cleaners Contact The Supplier Mighty Mike specialty tablets for many industries including Bacterial additives for the municipal commercial onsite and portable wastewater industries Decalcification for calcium buildup prevention in fixtures and plumbing or try our grease eating Tablets FOGHog for pump stations wet wells and municipal plants Decalcify CPT your pipes lines and drains to reduce eliminate and prevent the accumulation of scale and calcium build up in plumbing fixtures Bring back your system with Bacterial additive tablets U F BOOST for septic systems commercial wastewater treatment systems portable toilets or lagoons Biological Treatment Tablets Mighty Mike CPT Calcium Prevention Treatment Tablets Mighty Mike FOGHog Fats Oils Grease Treatment Tablets Mighty Mike U F BOOST BioRemediation Urine Feces Biological Treatment Tablets Need More Information Just Ask Click the button below to directly contact the supplier Use it to Ask a question Request more detailed information or literature Discuss your current project application Request a quote Locate a distributor in your area Schedule a demo Contact The Supplier Bio Microbics Inc Contact The Supplier Contact Details Company Profile MORE FROM Bio Microbics Inc Contact Details Company Name Bio Microbics Inc Address

    Original URL path: http://www.wateronline.com/doc/mighty-mike-maintenance-tablets-0001 (2016-02-14)
    Open archived version from archive

  • SewerGard 210 - Industrial Flyer
    Management Consumer Outreach Funding Labor Resiliency SCADA Automation Source Water All Source Water Contamination Desalination Water Scarcity Water Reuse Regulations and Legislation Providers YSI a Xylem brand Hach Company Schneider Electric Neptune Technology Group Inc Evoqua Water Technologies Veolia Water Solutions Technologies ABB Measurement Products Aclara Jacobi Carbons Endress Hauser Inc KROHNE Inc Kaeser Compressors Inc Emerson Process Management Rosemount Analytical Degremont Technologies Brentwood Industries View All Providers Product Service SewerGard 210 For Ultra Corrosive Industrial Wastewater Environments Source Sauereisen Inc Sauereisen SewerGard Industrial No 210 is a novolac epoxy that is specifically formulated for industrial wastewater environments where plants and refineries treat contaminated water before it is sent to a municipal wastewater treatment plant Contact The Supplier Click Here To Download SewerGard 210 Industrial Flyer Established in 1899 Sauereisen delivers the credibility that can only be attained by a history of success From collection systems to treatment plants Sauereisen offers the technology and experience to generate confidence Need More Information Just Ask Click the button below to directly contact the supplier Use it to Ask a question Request more detailed information or literature Discuss your current project application Request a quote Locate a distributor in your area Schedule a

    Original URL path: http://www.wateronline.com/doc/sewergard-industrial-0002 (2016-02-14)
    Open archived version from archive



  •